Description
- Specifications
Input
Rated power/ frequency NE200-2Sxxxx: 1-phase 200V ~ 240V; 50Hz/60Hz
NE200-4Txxxx: 3-phase 380V ~ 440V; 50Hz/60HzVoltage range NE200-2Sxxxx: 176V ~ 264V; Voltage unbalance degree: < 3% ; permissible frequency fluctuation: ±5%
NE200-4Txxxx: 304V ~ 456V; Voltage unbalance degree: < 3% ; permissible frequency fluctuation: ±5%Output
Voltage range NE200-2Sxxxx: 0~200V/440V; NE200-4Txxxx: 0~380V/440V Overload capacity Type G: 150% rated current 1min, 180% rated current 20s
Type P: 120% rated current 1min, 150% rated current 1sControl features
Control mode Vector control with PG(VC) Vector control without PG(SVC) V/F control Startup torque —- 0.5Hz 150% 1.5Hz 150% Speed adjustable range —- 1:100 1:50 Speed stabilization precision —- ± 0.2% ± 0.5% Torque control —- Yes N/A Torque precision —- ± 10% —- Torque response time —- <20ms —- Product functions
Key functions Torque/speed control mode switching, Multi-function input/ output terminals, under voltage regulation, AC operation grounding switching, torque limit, multi step operation, slip compensation, PID regulation, simple PLC, current control, manual/ automatic torque boost, current limit, AVR function Frequency setup Keypad, terminal Up/Down, Communication, Analog input AI1/AI2 Output frequency 0.00~550.0Hz Startup frequency 0.00~60.00Hz Acc/Dec time 0.01~3600.0s Dynamic braking 400V drive: braking unit action voltage: 650 ~ 750V;
200V drive: braking unit action voltage: 360 ~ 390V;DC injection braking DC braking activation frequency: 0.00 ~ 550.0Hz
DC braking current: G type 0.0 ~ 100.0%; P type 0.0 ~ 80.0%
DC braking time: 0.0 ~ 30.0s; Quick DC brake activation without lag timeMagnetic flux braking Fast deceleration through adding motor magnetic flux Unique functions
Parameter cloning Parameter upload, download. User can forbid the overwriting of the uploaded parameters. Protection function
Power undervoltage/overvoltage protection, overcurrent protection, IGBT protection, heatsink overheat protection, drive overload protection, motor overload protection, External devices faults protection, output phase-to-phase short-circuit protection, Abnormal power failure in running, power supply trip, output phase loss, EEPROM trip, Analog input trip, communication trip, version compatibility trip, cloning trip, hardware overload protection Environment
Application environment Vertical installation in well ventilated cabinet. Horizontal or other installation are forbidden. The cooling medium is air. Free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam, and water drop. Ambient temperature -10~+40°C, deration is required from 40 to 50°C, rated output current decreasing 1% per 1°C temperature higher Humidity 5~95% without condensation Altitude 0~2000m, deration is required for more than 1000 meters, at rated output current decreasing 1% per 1 00m higher Vibration 3.5mm, 2~9Hz; 10 m/s2, 9~200Hz; 15 m/s2, 200~500Hz Storage temperature -40~+70°C Structure
Protection level IP20 Cooling Fan air cooling
Reviews